The instruction manual is an integral part of the product.Pellet StoveP963 - P963 C - P963 D - P963 MINSTRUCTIONS FOR INSTALLATION,USE AND MAINTENANCE
This kind of installation provides the natural draft that results from a vertical rise avoiding smoke being released into the house when electricity t
The stove may be connected to an existing Class A chimney or a masonry chimney which meets the minimum requirements of NFPA 211. Using this kind of in
This kind of installation also provides natural draft in the event of a power failure.When installing as a hearth mount stove into a rebox the unit m
This conguration will help prevent blockage of vent by snow drifts. Also the minimum vertical run of 5 feet (1,5 m) ensures the ventilation of the ex
In determining optimum vent termination, carefully evaluate external conditions especially when venting directly through a wall. Since you must deal w
• The exhaust termination location (Fig. 21) must be at least: - 1’ (305 mm) above the ground level. Attention : the minimum vertical rise shall alway
FLOORPROTECTIONFLOORMETAL CHASSISABFig. 22 The stove has been tested and listed for mobile home installations.Unit must be installed in accordance wit
Cladding: ...in hand-made majolicaInterior: ...in steelBafe plate and hearth: ...in cast ironGrate
DescriptionNTC 10K room sensor In kitFlexible cable In kitLCD Remote-control In kitHot air ow diverter tool In kitGrate bafe plate In kitHex-wrench
2.5 DIMENSIONAL DIAGRAM P9632.6 DIMENSIONAL DIAGRAM P963 C22,48"(571 mm)20,81"(528 mm)46,33"(1177 mm)7"(178 mm)14,27"(362 m
Dear Customer,Thank you for having chosen one of our products, which is the result of years of experience and continuous research aimed at making a su
2.7 DIMENSIONAL DIAGRAM P963 DØØ22,6"(574 mm)20,3"(516 mm)46,13"(1172 mm)7"(178 mm)14,27"(362 mm)2,95"(75 mm)2,44"
DT2033860-032.9 WIRING DIAGRAM P963AL1NAL2ACC.COC.FUMISCAM.FNSERIALETERM.-TC1+N.AMB.N.H2ON.PEL.BLUGND+5VENCFAN1FAN2DISPLAYSPEEDFUN1FUN1SCAMBFUN2AUXSP
The wood pellet is obtained by pressing wood sawdust left over from the working of natural dried wood. The typical small, cylindrical form is obtained
Pursuant to current regulations on the safety of electrical equipment, you must contact your dealer or a qualied electrician for all and any work con
• The examples show the ducting of two fans. Each diagram gives just one example of the many possible solutions.Solution 1 - Fig. 30 - 31:The stove is
Solution 4 - Fig. 34:Extension of the previous solution, with the stove installed in the room to be heated and the air ow ducted to the front and the
Power cable (6)• The stove/replace comes with a power cable which must be connected to a 120V AC electrical outlet mains socket. Connection to the re
DT2010148-045.4 INSTALLING THE Y CONNECTOR (OPTIONAL)• The ducting of heat to adjoining rooms is at the user’s discretion according to requirements.•
6.0 USEThe pellet stove is a different type of heater. Its operation and maintenance differ from the traditional wood stove. Follow these operating i
DT2010220-076.2 REMOTE CONTROL• The pellet stove comes equipped with an LCD-display remote control and radio transmitter which allow you to operate i
1.0 GENERAL RULES 41.1 Soot inspection 41.2 Fresh air intake 51.3 Outside combustion air 51.4 Installation environment 61.5 Capacity load o
DT2010082-056.3 LIGHTING FOR THE FIRST TIME• Carefully read this “Instructions for Installation, Use and Maintenance“ in its entirety before lighting
STARTUPAction Description DisplayHold the ON/OFF key down for several seconds111CONTROL12:00 73FSTARTPHASE I1 2:00 73FSTARTPHASE II12:00 73FA cycle
Action Description DisplayPress theFAN keyand 111111LEVELP212:0073FSETPOWERP3SET VENT-102SET ROOMTEMPERAT.79FCLEANINGGRATE12:00 79FMAX
DT2012309-006.5 TROUBLESHOOTINGA list of situations that could occur and instructions on what to do is given below.FAILED IGNITIONAction Description
FAILED IGNITION: WHAT TO DOAction Description DisplayShut the stove downby pressing theON/OFF key down fora few secondsCLEANINGBRAZIER1 2:0022.c1• The
INTERRUPTION OF POWER SUPPLYAction Description DisplayIf there is a blackout while the stove is in normal heating operation, there are two possibiliti
DT2010222-076.6 CONTROL PANEL12313528746The stove is tted with a digital control panel to operate stove functions when the LCD remote control is una
DT2010247-076.8 PROGRAMMINGSETOPTESCMENURemote controlMENU• SELECT LANGUAGELANGUAGE ENGLISHLANGUAGE ITALIANOLANGUAGE DEUTSCHLANGUAGE FRANCAISSET• SET
UNIT OF MEASUREMENTFunction Action DisplaySelecting the UNIT OF MEASUREM menuPress the MENU button, use the MENU SELECTION button to select the UNIT O
SET CLOCK (current day/time)Function Action DisplaySet the dayPress the MENU key, select the SET CLOCK menu using the SELECT MENU key, then conrm by
Ensure that the installation of your product conforms to all the indications given below.1.0 GENERAL RULESWe recommend that the ue must have a chamb
DT2010242-056.11 TIMERFunction Action DisplaySelect set chrono menuPress the MENU key. Using the SELECT MENU key select the SET CHRONO menu and conrm
Function Action DisplaySet shutdown time for 1st operating cyclePress SELECT MENU to set the shutdown time, advancing in ten-minute jumps (for example
Function Action DisplaySelect set chrono menuPress the MENU key. Using the SELECT MENU key select the SET CHRONO menu and conrm by pressing the SET k
Function Action DisplaySet desired power for rst operating cyclePress SELECT MENU to set the desired power (for example you want power setting 1). Co
Function Action DisplaySelect set chrono menuPress the MENU key. Using the SELECT MENU key select the SET CHRONO menu and conrm by pressing the SET k
Function Action DisplaySet desired power for rst operating cyclePress SELECT MENU to set the desired power (for example you want power setting 1). Co
FAN MODEThis function allows you to have the two fans operating at the same speed (NORMAL FANS) or at different speeds (SEPARATE FANS). To make the mo
MULTICOMFORTThis function is used to choose the sensor for reading the room temperature: from the stove or from the remote control. To make the most o
ENERGY SAVINGFunction Action DisplaySelect the ENERGY SAVING menuPress the MENU key, then using the SELECT MENU key select the ENERGY SAVING function
DT2011866-006.14 PARAMETER MENUThe User can only interact with the MEMORY COUNTERS, the POWER OUTAGE and the EXTERNAL THERMOSTAT in the parameter menu
2" O.D.COMBUSTION AIR TUBETo ensure trouble-free operation the stove must have the necessary air available for combustion and this is provided th
POWER OUTAGEFunction Action DisplaySelection of parameter menuPress the MENU key. Using the SELECT MENU key select the PARAMETER MENU and conrm by pr
EXTERNAL THERMOSTATFunction Action DisplaySelection of parameter menuPress the MENU key. Using the SELECT MENU key select the PARAMETER MENU and conr
Selection of the external thermostat modeEXTERNAL THERMOSTAT: SHUT DOWNThis mode requires insertion of a DELAY time ranging from 20 minutes to 60 minu
ENABLE BEEP (audio signal)Function Action DisplaySelect enable beep menuPress the MENU key. Using the SELECT MENU key select the “ENABLE BEEP” menu an
The pellet stove with ‘Multifuoco System’ is tted with one/two fans for the circulation of hot air according to the model.This system allows several
DT2010994-006.19 SAFETY DEVICES a During operation some parts of the stove (door, handle, ceramic parts) can reach high temperatures.Remember to maint
Description of activity DisplayThe door open sensor veries that the door to the appliance has been correctly closed.WHEN ACTIVATED:If the door remain
PELLET HOPPER HOUSING TEMPERATURESensor Description DisplayThermostat with automatic resetLocated on the pellet hopper, its function is to prevent exc
FLUE GAS TEMPERATURE SENSORSensor Description DisplaySmoke sensorConnected to the electronic board, it constantly monitors the working temperature all
DT2010087-046.20 OPENING THE DOOR a During operation the door must remain closed.It is to be opened only when the stove has been shut down and cooled
DT2010033-011.4 INSTALLATION ENVIRONMENTContact local building authority before installation to determine if a permit and/or inspection is required.W
7.0 MAINTENANCEPursuant to current regulations on the safety of electrical equipment, you must contact your dealer or a qualied electrician for all
DT2011697-007.3 CLEANING THE FIREBOXOnce a week clean the rebox as follows. - Remove the grate bafe. - Remove the grate. - Remove the upper bafe p
DT2010092-037.5 CLEANING THE FLUE SYSTEMFig. 72 Soot and Flyash: formation and need for removal.The products of combustion will contain small particl
DT2010093-067.9 REPLACING THE WINDOWThe stove is tted with a 0.197” / (5 mm) thick ceramic glass panel, resistant to thermal shock up to 1382°F / (7
DT2010096-047.12 WHEN NOT IN USEWhen shutting the stove down for the summer, proceed as follows: - remove all pellets from the hopper and feeding auge
Problem Cause Solution a Some of the problems indicated below may be resolved by following the instructions. All work must be carried out when the app
Pressure switch malfunction“ALF 2” stove statusFaulty pressure switchReplace the pressure switch (use only original spares)No power supply to the auge
Stove safety device“MASS TEMP” stove statusBlocked ue or ue gas outlet Clean the ue and the outletFaulty electronic boardReplace the electronic boa
a This instruction booklet contains all the necessary information for installation, operation and maintenance.Only call the Gruppo Piazzetta S.p.A. s
DT2010557-028.1 REPLACING THE FUSESElectronic board fuse.Unscrew the cartridge fuse or safety plug from the electronic board and replace with a simil
SEE VENTMANUFACTURER'SINSTRUCTIONSMIN 4"4"6"6"32"FLOOR PROTECTIONREAR WALLSIDE WALLHEAT RADIATION AREA6"6"4&qu
H07032120 / DT2002308 – 0070English
H07032120 / DT2002308 – 0071English
Via Montello, 2231011 Casella d’Asolo (TV) - ITALYTel. +39.04235271 - Fax +39.042355178www.piazzetta.ite-mail:[email protected] ANY SERVIC
a The stove requires a UL listed pellet vent. So the venting system shall be approved for pellet stoves by a certied testing Laboratory. a PL Vent m
H MIN 5'H MIN 13'INSULATINGMATERIALTEETEEDIRECTIONOF CLEANINGDIRECTIONOF CLEANINGDIRECTIONOF CLEANINGTEEPELLETSTOVE0 ÷ 10'MIN 3%SEE VEN