P963 - P963 C - P963 D - P963 M
INSTRUCTIONS FOR INSTALLATION,
USE AND MAINTENANCE
Please read this entire manual before installation and use of this
pellet fuel-burning room heater. Failure to follow these instructions
could result in property damage, bodily injury or even death.
Save these Instructions.
Contact local building or re ofcials about restrictions and
installation inspection requirements in your area.
English
Przeglądanie stron 0
1 2 3 4 5 6 ... 71 72

Podsumowanie treści

Strona 1 - Pellet Stove

The instruction manual is an integral part of the product.Pellet StoveP963 - P963 C - P963 D - P963 MINSTRUCTIONS FOR INSTALLATION,USE AND MAINTENANCE

Strona 2 - IMPORTANT INFORMATION

This kind of installation provides the natural draft that results from a vertical rise avoiding smoke being released into the house when electricity t

Strona 3 - CONTENTS

The stove may be connected to an existing Class A chimney or a masonry chimney which meets the minimum requirements of NFPA 211. Using this kind of in

Strona 4 - 1.0 GENERAL RULES

This kind of installation also provides natural draft in the event of a power failure.When installing as a hearth mount stove into a rebox the unit m

Strona 5 - 1.3 OUTSIDE COMBUSTION AIR

This conguration will help prevent blockage of vent by snow drifts. Also the minimum vertical run of 5 feet (1,5 m) ensures the ventilation of the ex

Strona 6 - 1.4 INSTALLATION ENVIRONMENT

In determining optimum vent termination, carefully evaluate external conditions especially when venting directly through a wall. Since you must deal w

Strona 7 - 1.6 MINIMUM SAFETY DISTANCES

• The exhaust termination location (Fig. 21) must be at least: - 1’ (305 mm) above the ground level. Attention : the minimum vertical rise shall alway

Strona 8 - 1.7 FLUEWAY

FLOORPROTECTIONFLOORMETAL CHASSISABFig. 22 The stove has been tested and listed for mobile home installations.Unit must be installed in accordance wit

Strona 9 - TEE W/TEE CAP

Cladding: ...in hand-made majolicaInterior: ...in steelBafe plate and hearth: ...in cast ironGrate

Strona 10 - H07032120 / DT2002308 – 00

DescriptionNTC 10K room sensor In kitFlexible cable In kitLCD Remote-control In kitHot air ow diverter tool In kitGrate bafe plate In kitHex-wrench

Strona 11 - Fig. 14

2.5 DIMENSIONAL DIAGRAM P9632.6 DIMENSIONAL DIAGRAM P963 C22,48"(571 mm)20,81"(528 mm)46,33"(1177 mm)7"(178 mm)14,27"(362 m

Strona 12 - Fig. 16

Dear Customer,Thank you for having chosen one of our products, which is the result of years of experience and continuous research aimed at making a su

Strona 13 - Fig. 18

2.7 DIMENSIONAL DIAGRAM P963 DØØ22,6"(574 mm)20,3"(516 mm)46,13"(1172 mm)7"(178 mm)14,27"(362 mm)2,95"(75 mm)2,44"

Strona 14 - Fig. 20

DT2033860-032.9 WIRING DIAGRAM P963AL1NAL2ACC.COC.FUMISCAM.FNSERIALETERM.-TC1+N.AMB.N.H2ON.PEL.BLUGND+5VENCFAN1FAN2DISPLAYSPEEDFUN1FUN1SCAMBFUN2AUXSP

Strona 15 - Fig. 21

The wood pellet is obtained by pressing wood sawdust left over from the working of natural dried wood. The typical small, cylindrical form is obtained

Strona 16 - 1.15 MOBILE HOME INSTALLATION

Pursuant to current regulations on the safety of electrical equipment, you must contact your dealer or a qualied electrician for all and any work con

Strona 17 - 2.2 TECHNICAL DATA

• The examples show the ducting of two fans. Each diagram gives just one example of the many possible solutions.Solution 1 - Fig. 30 - 31:The stove is

Strona 18 - SERIAL NUMBER

Solution 4 - Fig. 34:Extension of the previous solution, with the stove installed in the room to be heated and the air ow ducted to the front and the

Strona 19 - 2.5 DIMENSIONAL DIAGRAM P963

Power cable (6)• The stove/replace comes with a power cable which must be connected to a 120V AC electrical outlet mains socket. Connection to the re

Strona 20 - Dimensions in inches (mm)

DT2010148-045.4 INSTALLING THE Y CONNECTOR (OPTIONAL)• The ducting of heat to adjoining rooms is at the user’s discretion according to requirements.•

Strona 21 - Ventilation

6.0 USEThe pellet stove is a different type of heater. Its operation and maintenance differ from the traditional wood stove. Follow these operating i

Strona 22 - 3.0 FUEL

DT2010220-076.2 REMOTE CONTROL• The pellet stove comes equipped with an LCD-display remote control and radio transmitter which allow you to operate i

Strona 23 - Deectors

1.0 GENERAL RULES 41.1 Soot inspection 41.2 Fresh air intake 51.3 Outside combustion air 51.4 Installation environment 61.5 Capacity load o

Strona 24 - Fig. 33

DT2010082-056.3 LIGHTING FOR THE FIRST TIME• Carefully read this “Instructions for Installation, Use and Maintenance“ in its entirety before lighting

Strona 25 - HOT AIR OUTLET VENT

STARTUPAction Description DisplayHold the ON/OFF key down for several seconds111CONTROL12:00 73FSTARTPHASE I1 2:00 73FSTARTPHASE II12:00 73FA cycle

Strona 26 - Fig. 45 Fig. 46

Action Description DisplayPress theFAN keyand 111111LEVELP212:0073FSETPOWERP3SET VENT-102SET ROOMTEMPERAT.79FCLEANINGGRATE12:00 79FMAX

Strona 27

DT2012309-006.5 TROUBLESHOOTINGA list of situations that could occur and instructions on what to do is given below.FAILED IGNITIONAction Description

Strona 28 - 6.0 USE

FAILED IGNITION: WHAT TO DOAction Description DisplayShut the stove downby pressing theON/OFF key down fora few secondsCLEANINGBRAZIER1 2:0022.c1• The

Strona 29 - 6.2 REMOTE CONTROL

INTERRUPTION OF POWER SUPPLYAction Description DisplayIf there is a blackout while the stove is in normal heating operation, there are two possibiliti

Strona 30 - 09 :53 68F

DT2010222-076.6 CONTROL PANEL12313528746The stove is tted with a digital control panel to operate stove functions when the LCD remote control is una

Strona 31

DT2010247-076.8 PROGRAMMINGSETOPTESCMENURemote controlMENU• SELECT LANGUAGELANGUAGE ENGLISHLANGUAGE ITALIANOLANGUAGE DEUTSCHLANGUAGE FRANCAISSET• SET

Strona 32

UNIT OF MEASUREMENTFunction Action DisplaySelecting the UNIT OF MEASUREM menuPress the MENU button, use the MENU SELECTION button to select the UNIT O

Strona 33 - 6.5 TROUBLESHOOTING

SET CLOCK (current day/time)Function Action DisplaySet the dayPress the MENU key, select the SET CLOCK menu using the SELECT MENU key, then conrm by

Strona 34

Ensure that the installation of your product conforms to all the indications given below.1.0 GENERAL RULESWe recommend that the ue must have a chamb

Strona 35 - 12:0073F

DT2010242-056.11 TIMERFunction Action DisplaySelect set chrono menuPress the MENU key. Using the SELECT MENU key select the SET CHRONO menu and conrm

Strona 36 - 6.7 SETTING THE LANGUAGE

Function Action DisplaySet shutdown time for 1st operating cyclePress SELECT MENU to set the shutdown time, advancing in ten-minute jumps (for example

Strona 37 - 6.8 PROGRAMMING

Function Action DisplaySelect set chrono menuPress the MENU key. Using the SELECT MENU key select the SET CHRONO menu and conrm by pressing the SET k

Strona 38

Function Action DisplaySet desired power for rst operating cyclePress SELECT MENU to set the desired power (for example you want power setting 1). Co

Strona 39 - 6.10 PROGRAMMING THE CLOCK

Function Action DisplaySelect set chrono menuPress the MENU key. Using the SELECT MENU key select the SET CHRONO menu and conrm by pressing the SET k

Strona 40 - 6.11 TIMER

Function Action DisplaySet desired power for rst operating cyclePress SELECT MENU to set the desired power (for example you want power setting 1). Co

Strona 41

FAN MODEThis function allows you to have the two fans operating at the same speed (NORMAL FANS) or at different speeds (SEPARATE FANS). To make the mo

Strona 42

MULTICOMFORTThis function is used to choose the sensor for reading the room temperature: from the stove or from the remote control. To make the most o

Strona 43

ENERGY SAVINGFunction Action DisplaySelect the ENERGY SAVING menuPress the MENU key, then using the SELECT MENU key select the ENERGY SAVING function

Strona 44

DT2011866-006.14 PARAMETER MENUThe User can only interact with the MEMORY COUNTERS, the POWER OUTAGE and the EXTERNAL THERMOSTAT in the parameter menu

Strona 45

2" O.D.COMBUSTION AIR TUBETo ensure trouble-free operation the stove must have the necessary air available for combustion and this is provided th

Strona 46

POWER OUTAGEFunction Action DisplaySelection of parameter menuPress the MENU key. Using the SELECT MENU key select the PARAMETER MENU and conrm by pr

Strona 47 - 6.13 ENERGY SAVING

EXTERNAL THERMOSTATFunction Action DisplaySelection of parameter menuPress the MENU key. Using the SELECT MENU key select the PARAMETER MENU and conr

Strona 48

Selection of the external thermostat modeEXTERNAL THERMOSTAT: SHUT DOWNThis mode requires insertion of a DELAY time ranging from 20 minutes to 60 minu

Strona 49 - 6.14 PARAMETER MENU

ENABLE BEEP (audio signal)Function Action DisplaySelect enable beep menuPress the MENU key. Using the SELECT MENU key select the “ENABLE BEEP” menu an

Strona 50

The pellet stove with ‘Multifuoco System’ is tted with one/two fans for the circulation of hot air according to the model.This system allows several

Strona 51

DT2010994-006.19 SAFETY DEVICES a During operation some parts of the stove (door, handle, ceramic parts) can reach high temperatures.Remember to maint

Strona 52

Description of activity DisplayThe door open sensor veries that the door to the appliance has been correctly closed.WHEN ACTIVATED:If the door remain

Strona 53 - 6.16 STOVE STATUS

PELLET HOPPER HOUSING TEMPERATURESensor Description DisplayThermostat with automatic resetLocated on the pellet hopper, its function is to prevent exc

Strona 54

FLUE GAS TEMPERATURE SENSORSensor Description DisplaySmoke sensorConnected to the electronic board, it constantly monitors the working temperature all

Strona 55 - 6.19 SAFETY DEVICES

DT2010087-046.20 OPENING THE DOOR a During operation the door must remain closed.It is to be opened only when the stove has been shut down and cooled

Strona 56

DT2010033-011.4 INSTALLATION ENVIRONMENTContact local building authority before installation to determine if a permit and/or inspection is required.W

Strona 57

7.0 MAINTENANCEPursuant to current regulations on the safety of electrical equipment, you must contact your dealer or a qualied electrician for all

Strona 58 - 12:00TON

DT2011697-007.3 CLEANING THE FIREBOXOnce a week clean the rebox as follows. - Remove the grate bafe. - Remove the grate. - Remove the upper bafe p

Strona 59 - 6.22 DISPOSAL OF ASHES

DT2010092-037.5 CLEANING THE FLUE SYSTEMFig. 72 Soot and Flyash: formation and need for removal.The products of combustion will contain small particl

Strona 60 - 7.0 MAINTENANCE

DT2010093-067.9 REPLACING THE WINDOWThe stove is tted with a 0.197” / (5 mm) thick ceramic glass panel, resistant to thermal shock up to 1382°F / (7

Strona 61 - 7.3 CLEANING THE FIREBOX

DT2010096-047.12 WHEN NOT IN USEWhen shutting the stove down for the summer, proceed as follows: - remove all pellets from the hopper and feeding auge

Strona 62 - 7.5 CLEANING THE FLUE SYSTEM

Problem Cause Solution a Some of the problems indicated below may be resolved by following the instructions. All work must be carried out when the app

Strona 63 - INIZIALE

Pressure switch malfunction“ALF 2” stove statusFaulty pressure switchReplace the pressure switch (use only original spares)No power supply to the auge

Strona 64 - 7.13 SCHEDULED MAINTENANCE

Stove safety device“MASS TEMP” stove statusBlocked ue or ue gas outlet Clean the ue and the outletFaulty electronic boardReplace the electronic boa

Strona 65 - 8.0 TROUBLESHOOTING

a This instruction booklet contains all the necessary information for installation, operation and maintenance.Only call the Gruppo Piazzetta S.p.A. s

Strona 66

DT2010557-028.1 REPLACING THE FUSESElectronic board fuse.Unscrew the cartridge fuse or safety plug from the electronic board and replace with a simil

Strona 67

SEE VENTMANUFACTURER'SINSTRUCTIONSMIN 4"4"6"6"32"FLOOR PROTECTIONREAR WALLSIDE WALLHEAT RADIATION AREA6"6"4&qu

Strona 68

H07032120 / DT2002308 – 0070English

Strona 69 - 8.1 REPLACING THE FUSES

H07032120 / DT2002308 – 0071English

Strona 70

Via Montello, 2231011 Casella d’Asolo (TV) - ITALYTel. +39.04235271 - Fax +39.042355178www.piazzetta.ite-mail:[email protected] ANY SERVIC

Strona 71

a The stove requires a UL listed pellet vent. So the venting system shall be approved for pellet stoves by a certied testing Laboratory. a PL Vent m

Strona 72 - Via Montello, 22

H MIN 5'H MIN 13'INSULATINGMATERIALTEETEEDIRECTIONOF CLEANINGDIRECTIONOF CLEANINGDIRECTIONOF CLEANINGTEEPELLETSTOVE0 ÷ 10'MIN 3%SEE VEN